Baxter International · Model Flo-Gard 6301
Configurable settings allow the pump to be custom-tailored to best suit the hospital’s needs Safety clamp automatically occludes the tubing when the pump door is opened Occlusion sensors detect both upstream and downstream restrictions Sensitivity of the downstream occlusion sensors are selectable through the pump’s configuration Volume-Time programming automatically calculates flow rate Easily replaceable fuse, battery, and power cord Dual channel pump (Functions as two 6201’s in a single unit) with independent controls Automatic Restart once occlusion clears Automatic Piggybacking of secondary medications Flow Check Occlusion Alarm offers an in-line resistance display of incremental back pressure Slide Clamp option offers an additional step to protect against inadvertent gravity-free flow Flow Rate Calculation is automatic after volume and time are selected Front Panel Lock-out protects against tampering User-adjustable occlusion pressures
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Occlusion alarm, no flow, upstream pressure high.
Root cause: Kinked set, clamped line, patient vein issue.
Symptoms: Air-in-line alarm, infusion paused.
Root cause: Air in set, improperly primed tubing.
Symptoms: Stalled infusion, inaccurate rate.
Root cause: Peristaltic motor or encoder wear.
Symptoms: Set not recognized, door-open error.
Root cause: Dirty or failed door microswitch.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Common R&R on high-mileage pumps.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Peristaltic roller / pump mechanism Common R&R on high-mileage pumps. | Periodic replacement | $$$ | Difficult |
| Air detector / ultrasonic sensor | Periodic replacement | $$ | Moderate |
| Door microswitch | Periodic replacement | $ | Fairly easy |
| Occlusion sensor assembly | Periodic replacement | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →