B. Braun · Model Perfusor Space Syringe Pump
Transport-Ready & Portable First syringe pump FDA-cleared for air and road transport Lightweight design (~3 lbs) for easy mobility Flexible mounting: vertical or horizontal positioning Advanced Safety Features Automatic syringe drive arm and piston brake to prevent unintended bolus Post-occlusion bolus reduction software enhances patient safety Clearly visible alarms with adjustable volume Flexible Dosing & Patient Support Supports weight-based dosing limits Customizable patient profiles with weight ranges Suitable for adults, pediatrics, and neonates Intuitive User Interface KeyGuard™ system with non-numeric keypad to reduce programming errors User-friendly navigation designed for clinical efficiency Standardized interface consistent with other Space infusion systems Modular & Scalable Design Independent modular system reduces risk of channel confusion Supports vertical stacking for space-saving configurations Ideal for multi-infusion setups Connectivity & Integration Wireless integration for system interoperability Compatible with broader infusion management systems Extensive drug library with customizable safety limits and advisories MRI Compatibility MR Conditional when used with SpaceStation MRI Enables continuous infusion during MRI procedures (Generated by AI)
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: The pump alarms and displays an error message / code and stops.
Root cause: A subsystem fault indexed in the service manual - motor / drive, a sensor, set-detection, or a board.
Symptoms: Repeated occlusion alarms, delivery stops, or an occlusion is missed.
Root cause: Kinked or clamped line, a closed roller clamp, a positional patient tube, pressure-sensor drift, or an improperly loaded set.
Symptoms: Frequent air-in-line alarms, delivery stops.
Root cause: Air in the set, an improperly loaded set, or an ultrasonic air-detector fault.
Symptoms: Delivered volume outside tolerance on the annual test, especially at low rates.
Root cause: Worn pumping mechanism / plunger drive.
Symptoms: Short run time, low-battery early after a full charge.
Root cause: Aged battery pack.
Symptoms: Set will not load, door will not latch, plunger grip poor.
Root cause: Worn door latch, plunger jaws, or anti-free-flow mechanism.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Battery pack | Periodic replacement | $$ | Fairly easy |
| Pumping mechanism / rotor / plunger drive | Major service part | $$$ | Difficult |
| Pressure / air-detector sensor assembly | Major service part | $$ | Moderate |
| Door / latch / anti-free-flow assembly | Major service part | $$ | Moderate |
| Drive motor / gearbox | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
From BioLab, for work done with this kind of equipment.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio