ARANX ROBOTICA CORP · Model MO-US-8001
The MotiliCap Data Recorder is used with the MotiliCap GI Monitoring System to receive and store transmitted data from the MotiliCap capsule during the time in the GI tract. The data is then downloaded from the recorder to a computer to be analyzed by the MotiliScan software for physician analysis.
Intended use: An assembly of devices designed to continuously measure and transmit signals for one or more gastrointestinal parameters (i.e., pH, pressure, temperature) or events (e.g., gastrointestinal bleeding) from a patient to a receiving location for viewing. It consists of a battery-powered capsule swallowed by the patient, and a patient-worn or clinician-held unit designed to wirelessly receive data from the capsule to either transmit it (i.e., a transceiver) to a computing device or to display it (e.g., a receiver); various solutions/containers may also be included. It is intended to help diagnose gastric pH disorders and/or measure gastrointestinal transit times to evaluate motility disorders.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: The patient monitoring is dead, reboots, or shuts down mid-use.
Root cause: Mains lead / fuse, an aged battery, or a power-supply board fault.
Symptoms: Short run time on battery; low-battery alarm soon after a full charge.
Root cause: Aged rechargeable battery pack or a charger fault.
Symptoms: Blank, dim or distorted display; unresponsive keys or touchscreen.
Root cause: Display, backlight, or control-board fault.
Symptoms: Power-on self-test or the scheduled performance check fails or is out of tolerance.
Root cause: Sensor drift or an internal board fault; recalibration or repair needed.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Rechargeable battery pack | Periodic replacement | $$ | Fairly easy |
| Power supply / mains board | Major service part | $$$ | Difficult |
| Display / control-panel assembly | Major service part | $$$ | Moderate |
| Cooling fan | Major service part | $ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio