Andersen Products · Model EO Gas 4
3.5-Hour Sterilization Achieves FDA-required 10-6 sterility assurance level for terminal sterilization of medical devices. Easy Installation Requires only a 120v or 240v outlet and a 1″ dedicated exhaust line. Lock Mechanism Door automatically locks at the start of the cycle and unlocks at the end. Active Aeration in Same Chamber Purge probe flushes the liner bag with a constant flow of fresh air at the end of the cycle – no need to transfer items to a separate area. EO-absorbent items may require additional aeration. 17.6g EO Cartridge Terminal sterility with 90% less EO than any other system on the market. Cartridge protects the hermetically sealed glass EO ampoule from accidental activation. Make your System Zero Emissions Andersen abators are a simple, cartridge-based system that employ a dry catalyst resin that converts ethylene oxide to biodegradable organic compounds. Replaceable abator cartridge has a 200 cycle capacity. Spent cartridges are non-hazardous. Free Operator Training It’s like having a sterilization expert on staff! Free operator training for the life of your sterilizer and free 24/7 support.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Cycle aborts, temperature or pressure not reached / held, failed BI or chemical indicator.
Root cause: Heater / element fault, a door-gasket leak, a steam-generation or water-fill fault, a blocked chamber drain / strainer, or a temperature / pressure-sensor fault.
Symptoms: Steam leak at the door, door will not seal, lock or unlock, pressure will not build.
Root cause: Worn door gasket or a door-lock / interlock fault.
Symptoms: Instruments / packs come out wet.
Root cause: Drying-phase vacuum / heater fault, an overloaded chamber, or a clogged drain.
Symptoms: Low-water alarm, mineral scale, cloudy chamber, poor steam quality.
Root cause: Empty or scaled reservoir, a fill-valve / pump fault, or use of non-distilled water.
Symptoms: Failed Bowie-Dick / air-removal test, slow come-up, air pockets.
Root cause: Blocked steam trap, a vacuum-pump / ejector fault, or a check-valve fault.
Symptoms: No or faint cycle printout.
Root cause: Thermal print head or paper.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Door gasket | Periodic replacement | $$ | Fairly easy |
| Heating element / steam-generator element | Major service part | $$$ | Difficult |
| Chamber / feedwater strainer & fill valve | Periodic replacement | $$ | Moderate |
| Temperature / pressure sensor | Major service part | $$ | Moderate |
| Steam trap / solenoid & check valves | Periodic replacement | $$ | Moderate |
| Thermal print head / paper | Periodic replacement | $ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.