Allied Healthcare Products · Model AutoVent 2000/3000/4000
Small, compact, and transport ready Designed to perform in harsh and toxic environments Assembles quickly with simplified operating instructions printed on the case Impact-resistant case with shock-absorbing bumpers and recessed control settings Rate and volume settings independently operated Easy-to-monitor patient valve assembly and toxic atmosphere valve are able to deliver additional breaths on demand by inspiratory effort of the patient Operates exclusively on standard 50 psi source gas, eliminating air entrainment and maintaining the integrity of the specified oxygen concentration Operates at extreme temperatures ranging from 0° F to 125° F Pneumatically powered … batteries not required Allows for PEEP attachment Meets ASTM, ISO and KKK-1822C standards.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Self-test aborts with a diagnostic code, circuit-leak or compliance test fails, ventilator not released for use.
Root cause: Patient-circuit leak, an exhalation-valve / flow-sensor fault, or an internal pneumatic / electronic fault (see the diagnostic-code table).
Symptoms: FiO2 not matching the setting, low or high supply-pressure alarm, gas-mix alarm.
Root cause: Blender / venturi fault or a low-flow O2 source issue.
Symptoms: Monitored tidal volume, pressure or flow implausible, frequent nuisance alarms.
Root cause: Flow sensor(s) or the internal pressure transducers aging or contaminated.
Symptoms: PEEP not held, auto-PEEP, high circuit pressure, exhalation-valve alarm.
Root cause: Worn or wet exhalation-valve diaphragm / assembly.
Symptoms: Short battery run time, will not ride through a power interruption, will not charge.
Root cause: Aged internal / external battery.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Flow sensor(s) | Frequent wear item | $$ | Fairly easy |
| Exhalation valve assembly | Frequent wear item | $$ | Fairly easy |
| O2 sensor (galvanic cell) | Frequent wear item | $$ | Fairly easy |
| Inlet filter / muffler | Frequent wear item | $ | Easy |
| Battery pack | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.