Aeonmed · Model Aeon 7200A
Precise Ventilation Performance Accurate and stable tidal volume delivery Minimum tidal volume of 20 mL for pediatric applications Suitable for both adult and pediatric patients Integrated Safety & Power Reliability Built-in power supply integration system Protection against voltage fluctuations and power failure Extended standby capability for uninterrupted operation Efficient Clinical Workflow One-touch switching between manual and mechanical ventilation Streamlined controls for faster operation Designed for ease of use in high-demand environments Advanced Monitoring Capabilities Large, high-resolution touchscreen display Simultaneous display of multiple waveforms and parameters Color-coded interface for improved visibility and interpretation User-Friendly Design Intuitive interface reduces training time Ergonomic layout for improved clinical efficiency Supports comprehensive patient monitoring (Generated by AI)
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: O2 low-pressure alarm, inability to ventilate.
Root cause: Pipeline disconnect or failed O2 flush valve.
Symptoms: Low minute volume, volume loss, leak alarm.
Root cause: Loose connections, torn bellows, cracked hose.
Symptoms: High scavenger pressure, agent smell in OR.
Root cause: Obstructed scavenger line or failed regulator.
Symptoms: Rising EtCO2, patient rebreathing.
Root cause: CO2 absorbent saturated.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Requires periodic calibration.
Consumable - replace on schedule.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| O2 pressure regulator | Periodic replacement | $$$ | Difficult |
| Vaporizer (agent-specific) Requires periodic calibration. | Major service part | $$$$ | Expert-level |
| Breathing circuit / bellows | Periodic replacement | $$ | Fairly easy |
| CO2 absorber canister Consumable - replace on schedule. | Consumable | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →