ACIST MEDICAL SYSTEMS, INC. · Model 019994
RXi Console with dPR, US (p/n: 800939-010 )
Intended use: A dedicated computer designed to calculate, store, and analyse haemodynamic parameters, and other cardiac-related measurements, based on data from catheterization laboratory monitoring/recording. Such data can be pressure measurements that are converted into useful parameters, e.g., cardiac output, pressure gradients, valve areas, shunt flows, vascular resistance, diastolic filling period or systolic ejection period. The computer may store these values chronologically, along with other physiologic events that occur during the procedure. This GMDN code may reflect old technology; its functions may be performed using off-the-shelf computer ware and dedicated software.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Will not arm, syringe will not fill / advance, flow or volume wrong, stalls under pressure.
Root cause: Air in the syringe / line, a syringe not seated, a drive-motor or plunger fault, or a self-test failure.
Symptoms: No response from the hand controller (AngioTouch) or the console touchscreen, cannot program or start.
Root cause: Hand-controller cable / contacts, or a display fault.
Symptoms: Frequent high-pressure or occlusion alarms with a patent line, or none when the line is blocked.
Root cause: Pressure transducer drift or a manifold / tubing-set issue.
Symptoms: Air not purged, spike not primed, contrast or saline not drawn.
Root cause: Spike set, air detector, or the priming sequence.
Symptoms: Console and injector head lose communication, will not initialise.
Root cause: Console-to-head cable or a control board.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Syringe drive motor / plunger assembly | Major service part | $$$ | Difficult |
| Hand controller (AngioTouch) | Periodic replacement | $$ | Easy |
| Pressure transducer | Periodic replacement | $$ | Moderate |
| Disposable syringe / manifold / tubing set | Consumable | $ | Easy |
| Console cable | Periodic replacement | $$ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.