ACIST MEDICAL SYSTEMS, INC. · Model 017987
HDi System Console, p/n 701460-007.
Intended use: An assembly of mains electricity (AC-powered) devices designed for extracorporeal and/or intracorporeal (endosonography or endoscopic) imaging procedures involving the heart and blood vessels. Included are software packages that support a variety of static or real-time cardiac specific imaging applications used to diagnose anatomical defects of the heart, determine blood flow characteristics and functional/anatomical problems associated with myocardial infarction. It is used to generate ultrasound pulses, direct them to a target area, detect the echoes, and process the resulting information to produce and display static or dynamic two or three-dimensional (3-D) images.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Will not arm, syringe will not fill / advance, flow or volume wrong, stalls under pressure.
Root cause: Air in the syringe / line, a syringe not seated, a drive-motor or plunger fault, or a self-test failure.
Symptoms: No response from the hand controller (AngioTouch) or the console touchscreen, cannot program or start.
Root cause: Hand-controller cable / contacts, or a display fault.
Symptoms: Frequent high-pressure or occlusion alarms with a patent line, or none when the line is blocked.
Root cause: Pressure transducer drift or a manifold / tubing-set issue.
Symptoms: Air not purged, spike not primed, contrast or saline not drawn.
Root cause: Spike set, air detector, or the priming sequence.
Symptoms: Console and injector head lose communication, will not initialise.
Root cause: Console-to-head cable or a control board.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Syringe drive motor / plunger assembly | Major service part | $$$ | Difficult |
| Hand controller (AngioTouch) | Periodic replacement | $$ | Easy |
| Pressure transducer | Periodic replacement | $$ | Moderate |
| Disposable syringe / manifold / tubing set | Consumable | $ | Easy |
| Console cable | Periodic replacement | $$ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.