ACCRIVA DIAGNOSTICS HOLDINGS, INC. · Model QV8
Avoximeter 4000 Cuvettes 100 cuvettes/box.
Intended use: A substance or reactant intended to be used together with a parent IVD to perform a specific function in an assay that is used for the quantitative measurement of one or multiple blood gas analytes in a clinical specimen.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: tHb, O2Hb, COHb or MetHb values implausible, QC out of range.
Root cause: Dirty or scratched cuvette optics, an air bubble / short sample in the cuvette, lamp aging, or calibration drift.
Symptoms: Low signal, will not read, lamp / reference-intensity warning.
Root cause: Optical source at end of life.
Symptoms: Bubble or short-sample errors, cuvette not detected.
Root cause: Air in the microcuvette, a worn cuvette, or a cuvette-detect sensor fault.
Symptoms: Will not power on, short battery life (portable models).
Root cause: Depleted or aged battery.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Optical source / lamp | Periodic replacement | $$ | Moderate |
| Microcuvettes | Frequent wear item | $ | Easy |
| Optical filter / detector assembly | Major service part | $$$ | Difficult |
| Battery (portable models) | Periodic replacement | $$ | Fairly easy |
| QC / calibration verification standard | Frequent wear item | $$ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.