Abbott · Model 2000
RhythmView Workstation, US.
Intended use: An assembly of devices designed to measure, process, and store electronic data for the interpretation of cardiac physiological parameters received from the output of connected measuring devices (e.g., body surface or intracardiac electrocardiograph (ECG) sensors, transducers, and catheters). The measurements can be compared to pre-established diagnostic criteria for parameters such as cardiac blood flow, electrical conduction, or heart chamber geometry. It typically consists of dedicated workstation, hardware and software that display real-time, three-dimensional (3-D) cardiac maps (e.g., electrical propagation, electrical potential, and cardiac chamber geometry maps), and a catheter.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Basket / catheter electrograms noisy, missing channels, or the map will not build.
Root cause: Basket catheter electrode contact / damage, a patient-cable / junction-box fault, or amplifier input noise.
Symptoms: Whole groups of channels drop, connector not recognised.
Root cause: Worn junction box or patient cable connector.
Symptoms: Application hangs, map export fails, will not launch a case.
Root cause: Workstation PC or software fault.
Symptoms: No map to the EP recording system or the lab displays.
Root cause: Video / network output fault.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Patient cable / junction box | Periodic replacement | $$$ | Easy |
| Basket mapping catheter | Consumable | $$ | Easy |
| Workstation PC | Major service part | $$$ | Moderate |
| Signal amplifier board | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.