Abbott Medical Optics · Model Optical Coherence Tomography
Advanced, high-resolution imaging Rapid Exchange Tip for easier loading and tracking Proprietary sheath design for continuous calibration throughout pullback Radiopaque markers - at the distal tip, imaging lens and 50 mm proximal to the lens - aid the physician in aligning the OCT pullback to region of interest Shaft markers - at 90 cm and 100 cm notify the physician when the distal tip is exiting the guide catheter 2.7 F low-profile tip Hydrophilic coating Compatible with standard 0.014" guide wires Compatible with D.2 and E.2 software or higher.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Noisy, dim or absent intravascular image, incomplete pullback.
Root cause: Imaging catheter / optical fibre damage, a drive-motor & optical-coupler (DOC) fault, or a laser / detection-engine fault.
Symptoms: Automated pullback does not run at the set rate, stalls, or the distance is wrong.
Root cause: Pullback drive motor / gearbox or the DOC coupling.
Symptoms: System does not recognise the imaging catheter, calibration fails.
Root cause: DOC connector wear or a damaged catheter hub.
Symptoms: Blood not adequately cleared, image obscured during acquisition.
Root cause: Injector interface / trigger or operator flush technique.
Symptoms: Angio co-registration (OPTIS) misaligns, display or export problems.
Root cause: Angio-interface or workstation fault.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Drive motor & optical coupler (DOC) | Periodic replacement | $$$$ | Moderate |
| Imaging catheter | Consumable | $$$ | Easy |
| Laser / detection engine | Major service part | $$$$ | Expert-level |
| Angio interface / co-registration hardware (OPTIS) | Major service part | $$$ | Moderate |
| Workstation PC / display | Major service part | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.