Abbott · Model ARCHITECT i4000SR
Users benefit from the seamless transfer from system to system. Equivalent results across all ARCHITECT i Systems Identical technology, reagents and assay protocols Identical software that is intuitive to operate Universal ARCHITECT sample carrier Users benefit from a unique approach to consolidation. No clinically significant sample tube to tube carryover (less than 0.1 ppm) Robotic Sample Handler (RSH) eliminates bottlenecks and prioritizes urgent requests Immediate STAT processing for fast and consistent turnaround time Up to 50 refrigerated reagent positions Continuous sample access loading of up to 285 samples via priority (35) and routine (250) areas Throughput of up to 400 immunoassay tests per hour Users benefit from the latest in immunoassay technology. CHEMIFLEX technology delivers flexible assay protocols with superior detection and extended linear ranges Up to 50 color-coded, refrigerated onboard reagent positions and flexible kit sizes of 100 or 500 tests provide high reagent test capacity of up to 25,000 tests to optimize walkaway time Liquid level sensing combined with pressure differential technology for enhanced bubble and clot detection ensures accurate sampling.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Controls out of range, calibration fails, flagged results on one or more assays.
Root cause: Reagent pack issue, a probe / dispense fault, incubation-temperature drift, or a detector / optics fault.
Symptoms: Short aspiration, no dispense, clot / level-sense errors, carryover.
Root cause: Clogged or bent probe, a syringe / pump fault, or a level-sense fault.
Symptoms: High background / noise, poor precision, elevated blanks.
Root cause: Blocked wash-station nozzles or a wash-pump / vacuum fault.
Symptoms: Assay drift or bias, incubation-temperature alarm.
Root cause: Incubator heater or temperature-sensor fault.
Symptoms: Low signal, high CV, detector-error message.
Root cause: PMT / detector ageing or an optics fault.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Sample / reagent probe | Periodic replacement | $$ | Moderate |
| Syringe / dispense pump | Periodic replacement | $$ | Moderate |
| Wash-station nozzles / pump tubing | Frequent wear item | $ | Moderate |
| Incubator heater / temperature sensor | Major service part | $$ | Moderate |
| Detector / PMT module | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.