Beckman Coulter · Model DXI 600
Onboard capacity of 50 refrigerated reagent packs enhance flexibility - configure the system menu to match your testing requirements Large on-board reagent capacity simplifies reagent management Bar-coded, liquid, ready-to-use reagents – no reagent preparation Standardized design of reagent packs across UniCel Access immunoassay systems Excellent correlation of results across platforms A broad menu across a wide variety of disease states enables your laboratory to consolidate workstations and recapture testing currently being sent out Rapid assay kinetics improve turn-around times System supports multiple assay protocols designed so assay performance is optimized Magnetic particle separation with enhanced chemiluminescent detection delivers exceptional clinical performance Large on-board capacity of up to 60 samples at once with continuous loading capability streamlines user sample processing Sample Racks are compatible with all UniCel systems, reducing sample handling across multiple systems Sample Racks can be loaded directly from the centrifuge, reducing manual processes and improving turn around times Routine sample loading can be interrupted to load STAT samples quickly "Point-in-space" pipetting technology aligned with CLSI guidelines allows integration with laboratory automation systems System releases the primary tube after creating an aliquot allowing for more efficient processing of samples Automatically creates aliquots based on the volume of requested tests System can be configured to aspirate additional volume required for user-defined reflex or re-run test scenarios System stores aliquots for up to three hours in a refrigerated low-evaporation compartment Simplifies inventory management - utilize same type of vessel for aliquots and reactions Load reagents and all consumables ‘on-the-fly’, without using the console computer or pausing the instrument, minimizing operator intervention Easy to use Windows based software Large volume supplies maximize walkaway capability Intuitive operator interface, with touch screen capability, maximizes efficiency Auto-matched pipettors work in parallel to deliver sample and reagent into the reaction vessels – and achieves a peak throughput of 200 tests per hour
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.