Abbott · Model ARCHITECT ci16200
Seamless transfer from system to system. Equivalent results across all ARCHITECT c Systems and i Systems. Identical technology, reagents and assay protocols. Identical software that is intuitive to operate. Universal ARCHITECT sample carrier. A unique approach to consolidation. SmartWash™ technology ensures no clinically significant sample tube to tube carryover (less than 0.1 ppm). Robotic Sample Handler (RSH) eliminates bottlenecks and prioritizes urgent requests. Immediate STAT processing for fast and consistent turnaround time. Up to 90 refrigerated reagent positions plus patented ISE (Na+, K+, and Cl-). 365 sample load capacity including 35 priority positions. Continuous sample access. Throughput of up to 1,800 clinical chemistry and up to 200 immunoassay tests per hour. The latest in immunochemistry technology. CHEMIFLEX™ technology delivers flexible assay protocols with superior detection and extended linear ranges. Integrated Chip Technology (ICT) delivers ISE (Na+, K+, and Cl-) analysis with minimal maintenance, low sample volume (15 uL), and within run precision 1% or less. Liquid level sensing combined with pressure differential technology for enhanced bubble and clot detection.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Controls out of range, calibration fails, flagged results on one or more assays.
Root cause: Reagent pack issue, a probe / dispense fault, incubation-temperature drift, or a detector / optics fault.
Symptoms: Short aspiration, no dispense, clot / level-sense errors, carryover.
Root cause: Clogged or bent probe, a syringe / pump fault, or a level-sense fault.
Symptoms: High background / noise, poor precision, elevated blanks.
Root cause: Blocked wash-station nozzles or a wash-pump / vacuum fault.
Symptoms: Assay drift or bias, incubation-temperature alarm.
Root cause: Incubator heater or temperature-sensor fault.
Symptoms: Low signal, high CV, detector-error message.
Root cause: PMT / detector ageing or an optics fault.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Sample / reagent probe | Periodic replacement | $$ | Moderate |
| Syringe / dispense pump | Periodic replacement | $$ | Moderate |
| Wash-station nozzles / pump tubing | Frequent wear item | $ | Moderate |
| Incubator heater / temperature sensor | Major service part | $$ | Moderate |
| Detector / PMT module | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.