ZOLL Medical · Model AED
Heart defibrillator has a built in Text Display with Voice Prompts FSA Eligible Analyzes heart rhythm and informs the rescuer if the rhythm is shockable or non-shockable. Delivers defibrillation treatment to victims of cardiac arrest who exhibit shockable ECG rhythms. Sequenced LED array gives fast communication of specific rescuer actions needed at the correct time. Voice prompts and graphics guide the rescuer regarding what to do and when to do it during a cardiac emergency - such as calling for help or giving CPR to the patient. Monitors the depth and rate of chest compressions during CPR and provides voice prompts Notifies user of good compressions that are at least 2 inches deep and at a rate of 100 per minute Notifies users if compressions are inadequate and when to push harder and/or faster Meets the FDA's guidelines for requiring that chest compressions be at least 2 inches deep Audible beeps encourage rescuers to provide CPR compressions at 100 CPM (requires Zoll CPR-D Padz) Performs periodic self test to ensure its continual readiness Unit cover functions as a Passive Airway Support System (PASS). Resists dust and water
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Short charge-hold, low-battery on readiness test.
Root cause: Aged battery pack.
Symptoms: No shock delivered, pad error.
Root cause: Worn paddles or expired pads.
Symptoms: Won't charge or discharges unexpectedly.
Root cause: Relay/contactor wear.
Symptoms: Leakage alarm, self-test fail.
Root cause: Failed isolation components.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Critical, keep charged spares.
Expiration-dated consumable.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Patient interface cable | Periodic replacement | $$ | Fairly easy |
| Rechargeable battery pack Critical, keep charged spares. | Periodic replacement | $$$ | Fairly easy |
| HV energy storage capacitor | Major service part | $$$$ | Expert-level |
| Defibrillation electrodes / pads Expiration-dated consumable. | Consumable | $$ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →