ZEISS · Model VISULAS YAG III Combi
Space saving and flexible - Both lasers also perform effectively as individual units. The VISULAS 532s can be used in the operating room while the VISULAS YAG III can continue to be used with the combi laser slit lamp. Only as much energy as necessary - The VISULAS YAG III Combi focuses the optimum amount of YAG laser energy directly to the target thanks to its Super-Gaussian beam profile. Variable focus shift - Depending on the procedure the focal point of the aiming beam is set precisely and reproducibly before, behind or directly at the focal point of the disruption laser Gentle laser treatment - The ParFocus™ zoom system of the VISULAS 532s delivers a homogeneous, sharply defined and reproducible laser spot on the retina and minimizes heat-related side-effects on the patient's cornea. Navigating with fingertip precision - The coagulation laser is always visible in the center of the slit lamp illuminated field thanks to the coaxial illumination and electronic micromanipulator integrated into the joystick of the combi slit lamp.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Dim illumination, lamp error.
Root cause: Xenon/LED aging.
Symptoms: No phaco power, error.
Root cause: Tip or handpiece wear.
Symptoms: Unstable anterior chamber.
Root cause: Peristaltic pump wear.
Symptoms: Blurry/offset image.
Root cause: Camera calibration drift.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
High-value, track usage.
Consumable.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Imaging camera module | Periodic replacement | $$$ | Difficult |
| Phaco handpiece / tip High-value, track usage. | Periodic replacement | $$$$ | Difficult |
| Illumination lamp / LED | Periodic replacement | $$$ | Moderate |
| Peristaltic pump tubing Consumable. | Frequent wear item | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.