ZEISS · Model CALLISTO eye
Integration into your workplace - CALLISTO eye® integrates seamlessly with OPMI® LUMERA® 700 superimposing the assistance functions in the eyepiece via IDIS (Integrated Data Injection System). Visualization and documentation - The live video is shown also in full screen ZEISS Toric Solution - Supporting you to make astigmatism correction a routine step in cataract surgery Assistance Functions: Incision/LRI Assistant - Superimpose templates of individual, planned incisions and limbal relaxing incisions e.g. for inserting a toric intraocular lens Rhexis Assistant - Superimpose individually scalable rings to support you in opening the capsular bag during capsulorhexis Z ALIGN – Toric Assistant - Define reference and target axes and display them onscreen and in the eyepiece, supporting you in the alignment of toric intraocular lenses K TRACK - In combination with a keratoscope, the assistant function visualizes corneal curvature in the patients' eyes
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Dim illumination, lamp error.
Root cause: Xenon/LED aging.
Symptoms: No phaco power, error.
Root cause: Tip or handpiece wear.
Symptoms: Unstable anterior chamber.
Root cause: Peristaltic pump wear.
Symptoms: Blurry/offset image.
Root cause: Camera calibration drift.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable.
High-value, track usage.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Illumination lamp / LED | Periodic replacement | $$$ | Moderate |
| Peristaltic pump tubing Consumable. | Frequent wear item | $ | Easy |
| Imaging camera module | Periodic replacement | $$$ | Difficult |
| Phaco handpiece / tip High-value, track usage. | Periodic replacement | $$$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.