NIDEK · Model AR-600/A
Lightweight, smaller and its sleek high tech design. The Nidek AR 600 Autorefractor auto alignment, focusing and patient measurements follow the same proven principles as the Marco automated refractors but quicker, rapid- fire readings give the operator instantaneous results. Lightweight, smaller and its new sleek high tech design is cosmetically appealing for any office environment. In addition to the standard printout which displays the patients prescription, the hard copy also displays EYE PRINT a unique graphic illustration showing the refractive state of the patients eye based on the measures value. Other features include: automatic near and far PD measurements, auto monitor shut-off, and interfacing capabilities.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Dim illumination, lamp error.
Root cause: Xenon/LED aging.
Symptoms: No phaco power, error.
Root cause: Tip or handpiece wear.
Symptoms: Unstable anterior chamber.
Root cause: Peristaltic pump wear.
Symptoms: Blurry/offset image.
Root cause: Camera calibration drift.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
High-value, track usage.
Consumable.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Imaging camera module | Periodic replacement | $$$ | Difficult |
| Phaco handpiece / tip High-value, track usage. | Periodic replacement | $$$$ | Difficult |
| Illumination lamp / LED | Periodic replacement | $$$ | Moderate |
| Peristaltic pump tubing Consumable. | Frequent wear item | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →