WELCH ALLYN, INC. · Model 901047
Welch Allyn CardioPerfect Workstation with PC-Based 12-Lead Resting Electrocardiograph, Noninterpretive, AHA ECG Cable, ABPM-7100S Ambulatory Blood Pressure System, PC-Based SpiroPerfect Spirometer
Intended use: An electrically-powered, noninvasive device designed to be worn by a patient (typically on the arm or wrist) during daily activities for 24-hour recording of blood pressure; it is not intended to detect cardiac arrythmias. The recorded measurements can be downloaded and analysed at a medical facility, typically using a computer with a dedicated software. The device typically incorporates display and controls and may include a cuff with connection tubing and/or calibration device.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Low O2 purity, alarm.
Root cause: Zeolite sieve exhaustion.
Symptoms: Low flow, overheat.
Root cause: Worn compressor.
Symptoms: Low vacuum, no suction.
Root cause: Diaphragm/motor wear.
Symptoms: No humidity, overheat.
Root cause: Heater plate failure.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Common R&R on concentrators.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Compressor | Periodic replacement | $$$ | Difficult |
| Suction diaphragm / pump | Periodic replacement | $$ | Moderate |
| Humidifier heating plate | Periodic replacement | $$ | Fairly easy |
| Sieve bed (zeolite) Common R&R on concentrators. | Periodic replacement | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.