VYAIRE MEDICAL, INC. · Model 7003300
AVEA Ventilator Nasogastric Pressure Monitoring Tube Set, 16 FR Adult.
Intended use: A hollow cylinder inserted orally or nasally into the trachea to provide an unobstructed airway to convey gases and vapours to and from the lungs during anaesthesia, resuscitation, and other situations where the patient is not properly ventilated; it does not include an antimicrobial agent(s). The device may: 1) be packaged with a connector that will attach to a breathing circuit or manual resuscitator; 2) have a distal inflatable cuff to seal against the tracheal wall; 3) be radiopaque; and 4) have a built-in pilot balloon for cuff pressure monitoring. It is available in various diameters and lengths for adult and paediatric patients. This is a single-use device.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Self-test aborts with a fault, circuit-leak or compliance test fails, ventilator will not be released for use.
Root cause: Patient-circuit leak, an exhalation-valve / flow-sensor fault, or an internal pneumatic fault.
Symptoms: FiO2 not matching the setting, low or high supply-pressure alarm, gas-mix alarm.
Root cause: Blender fault, a wall-supply / hose issue, or a failing internal compressor.
Symptoms: Monitored tidal volume, pressure or flow implausible, frequent nuisance alarms.
Root cause: Hot-wire / variable-orifice flow sensor or the internal pressure transducers aging or contaminated.
Symptoms: PEEP not held, auto-PEEP, high circuit pressure, exhalation-valve alarm.
Root cause: Worn or wet exhalation-valve diaphragm / assembly.
Symptoms: Short internal-battery run time, will not ride through a power interruption.
Root cause: Aged internal / external battery.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Flow sensor(s) | Frequent wear item | $$ | Fairly easy |
| Exhalation valve assembly | Frequent wear item | $$ | Fairly easy |
| O2 sensor (galvanic cell) | Frequent wear item | $$ | Fairly easy |
| Internal compressor | Major service part | $$$$ | Expert-level |
| Battery pack (internal / external) | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.