Utah Medical · Model Finesse
• Integrated Smoke Evacuation - The ESU-110 utilizes a design that integrates the electrosurgical generator and smoke evacuation system into a single compact unit. This results in an optimal design for operating areas with limited space, especially offices. It also allows simultaneous "single switch" activation of both modules by either the handswitch control pen or footswitch. • Controlled Output Circuitry - Incorporates controlled output circuitry to produce the best histological tissue specimen for the pathologist. Controlled output circuitry maintains the output voltage within the ideal cutting range to produce a specimen with minimal thermal damage at the margins. It also allows the generator to be set at a preferred 'cut' power output setting, but continuously adjusts itself to meet the minimum needs for optimal cutting. This eliminates any need to adjust the output setting when changing loop sizes. • Three-Stage Particle Filtration - The Generator utilizes a three-stage filtration system to evacuate and filter the smoke plume produced during electrosurgery. The filtration system includes an activated charcoal filter which absorbs odorous gases, and HEPA and ULPA filters which remove solid particles and aerosols. The 3 filters provide a minimum efficiency of 99.999% fr particles at 0.1 microns. • Safety - Each system meets ANSI/AAMI HF-18 standards for patient lead isolation. This provides protection for both patient and clinician by reducing the possibility of creating an alternate current path that could result in shock or burn. In addition, the systems will sound an alarm and automatically shut off should an interruption occur in the connection to the dispersive pad.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Poor cut/coag, sparking, low power.
Root cause: Burned/eroded blade or pencil.
Symptoms: Pad alarm, no activation.
Root cause: Poor contact or expired pad.
Symptoms: Unintended or no activation.
Root cause: Fluid ingress / worn switch.
Symptoms: Dim or dead panel, color shift.
Root cause: LED module aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Single-use; expiry critical.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Return electrode (patient plate) Single-use; expiry critical. | Consumable | $ | Easy |
| Foot switch assembly | Periodic replacement | $$ | Fairly easy |
| OR light LED module | Major service part | $$$ | Difficult |
| Table hydraulic actuator | Periodic replacement | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.