Unisyn Medical Technologies, Inc. · Model The Nickle
Serious Tool, Compact Design. The Nickel senses acoustic pulses emitted by elements of an ultrasonic array probe and generates a return acoustic signal simulating a target. The sensor is an integral PVDF transducer designed for direct contact to the lens of the probe. The PVDF transducer assembly has a "V" or "Barn Roof" plastic lens with a peak dimension small enough to allow only acoustic energy from a single element assuming the peak of the roof is parallel to the element. The PVDF material is broadband, thus signals from any diagnostic imaging probe can be sensed. The user knows that a signal has been received when the LED on The Nickel goes from red to green The received signal is amplified and then compared to a fixed reference level such that signals larger than the reference level indicate that an acoustic pulse has been received. Crossing this signal threshold level results in a digital signal that is sent to a CPLD (complex programmable logic device), which starts an oscillator (˜10 MHz) synchronous with the received pulse and contains counters used to generate three return targets back to the system. The first target signal is 10 MHz and is transmitted continuously for 2 cm of depth from 3 to 5 cm. The second target is 5 MHz and is transmitted from 5 to 7 cm and the third target frequency is 2.5 MHz and is transmitted from the 7 to 9 cm. These returning signals are then displayed in real-time on the system monitor at various depths within the image format.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Readings out of tolerance on verification check.
Root cause: Reference component aging.
Symptoms: Won't power on, unexpected shutdown mid-test.
Root cause: Aged internal battery or PSU.
Symptoms: Intermittent or no reading through a specific lead.
Root cause: Repeated connect/disconnect cycles.
Symptoms: Blank, frozen, or garbled display.
Root cause: Display module or driver board aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
High-turnover; keep spares.
Send out for annual re-certification.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Rechargeable battery pack | Periodic replacement | $$ | Fairly easy |
| Test lead set High-turnover; keep spares. | Periodic replacement | $$ | Easy |
| Display module | Major service part | $$$ | Difficult |
| Calibration reference module Send out for annual re-certification. | Major service part | $$$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →