Unisyn Medical Technologies, Inc. · Model iTest
Large graphics display with cursor selection of options and setup parameters. User selectable challenge (test) voltage, 90 to 275 VAC. User selectable challenge (test) frequency, 50 or 60 HZ. User selectable test limits by transducer manufacturer and model. 1% FS measurement accuracy. Automatic internal self test. Single button activated full system test. Simple Pass/Fail mode available. Analytical mode available. Digital calibration. User selectable display options. Battery life display (0% to 100%). Programmable backlight timer. Adjustable contrast. Upgradeable firmware. RS232 port and PC software available. Printer output port with programmable user header. Real time clock. Compatible with Dale technology and Fluke transducer adapters and dual conductivity probes. Meter mode (iTest Pro™ only). Programmable challenge (test) voltage and frequency (iTest Pro™ only). Programmable meter timer (iTest Pro™ only). Datalog with storage of 99 test records (iTest Pro™ only).
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Readings disagree with a reference standard, verification check outside tolerance.
Root cause: Normal drift - the instrument needs its scheduled factory / accredited calibration (at least every 12 months).
Symptoms: Dead unit, short battery life, will not charge.
Root cause: Depleted or aged battery, or a power / charger fault.
Symptoms: Open or intermittent readings, connection errors, a specific function fails.
Root cause: Worn or broken test leads, mains adapters, patient-lead adapters, or a sensor cable.
Symptoms: One parameter (leakage, insulation, ECG / SpO2 / IBP simulation, defib / pacer energy, ventilator flow / pressure, light / dose) errors or is out of range while others work.
Root cause: An internal source / measurement circuit fault on that channel.
Symptoms: The automation / logging software will not connect.
Root cause: USB cable / port or driver.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
At least every 12 months per the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Test-lead / adapter set | Periodic replacement | $$ | Easy |
| Battery | Periodic replacement | $$ | Easy |
| Calibration (factory / accredited) At least every 12 months per the manufacturer. | Frequent wear item | $$ | Easy |
| Communication cable | Periodic replacement | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.