Toshiba · Model Surginix SXT-2000A
High resolution image and Smart Operation Ability Large-capacity high-voltage generator the inverter-type high-voltage generator enables a high X-ray tube output and thus allows fluoroscopy to be performed for large patients too. A 1K × 1K CCD camera is incorporated A CCD camera with a high-modulation factor and a high contrast/MTF I.I. are incorporated, providing sharp images with high-contrast. Advanced applications DSA (Digital subtraction) is equipped as standard configuration. This system is compatible with DICOM 3.0. External storage of image Images can be stored on DVD/CD/USB storage devices. Touch Screen and LCD Display The intuitive design allows new users to operate the system with confidence. Laser Marking Device the high brightness laser pointer allows precise alignment, reduces unnecessary radiation exposure, and aids in tracking the region of interest. Smart Cable Guard The Wheels are fitted with the Smart Cable Guard. This eliminates cable disconnections whilst still being able to pass over smaller obstacles. Two LCD monitors are provided on the monitor cart, live images on the left monitor and reference images on the right monitor.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Tube won't fire, heat-capacity alarm.
Root cause: Filament wear, cooling failure.
Symptoms: Image noise, artifacts, low SNR.
Root cause: Flat-panel / sensor aging.
Symptoms: Tube temp alarm, duty-cycle limited.
Root cause: Pump/radiator or coolant loss.
Symptoms: Exposure fails, kV/mA out of range error.
Root cause: HV tank or generator board fault.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Major R&R; track mAs history.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| High-voltage generator | Major service part | $$$$ | Expert-level |
| Workstation RAID / GPU | Periodic replacement | $$$ | Difficult |
| X-ray tube insert Major R&R; track mAs history. | Major service part | $$$$ | Expert-level |
| Flat-panel detector | Major service part | $$$$ | Expert-level |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Synced live from the FDA openFDA API.
Images display with wrong patient demographics.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →