
Toshiba · Model Surginix SXT-2000A
High resolution image and Smart Operation Ability Large-capacity high-voltage generator the inverter-type high-voltage generator enables a high X-ray tube output and thus allows fluoroscopy to be performed for large patients too. A 1K × 1K CCD camera is incorporated A CCD camera with a high-modulation factor and a high contrast/MTF I.I. are incorporated, providing sharp images with high-contrast. Advanced applications DSA (Digital subtraction) is equipped as standard configuration. This system is compatible with DICOM 3.0. External storage of image Images can be stored on DVD/CD/USB storage devices. Touch Screen and LCD Display The intuitive design allows new users to operate the system with confidence. Laser Marking Device the high brightness laser pointer allows precise alignment, reduces unnecessary radiation exposure, and aids in tracking the region of interest. Smart Cable Guard The Wheels are fitted with the Smart Cable Guard. This eliminates cable disconnections whilst still being able to pass over smaller obstacles. Two LCD monitors are provided on the monitor cart, live images on the left monitor and reference images on the right monitor.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: No image on boost, exposure inhibited, kV/mA error, image too dark or bright.
Root cause: X-ray tube / monoblock fault, HV generator fault, or the AEC / dose-control loop.
Symptoms: Dim, distorted, vignetted or noisy image; dead lines (flat panel); S-distortion (II).
Root cause: Image-intensifier tube ageing / II fault, or a flat-panel detector fault.
Symptoms: Orbital, lateral or vertical motion binds, drifts, or a brake will not hold.
Root cause: Worn friction brakes, bearings, or the counterbalance.
Symptoms: No image on one or both monitors, image freeze, no last-image-hold.
Root cause: Monitor, the cart-to-stand cable, or the image-processing PC.
Symptoms: Fluoro inhibited after a run, tube-heat warning.
Root cause: Monoblock heat limit reached or a cooling-fan fault.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| X-ray tube / monoblock | Major service part | $$$$ | Expert-level |
| Image intensifier tube / camera | Major service part | $$$$ | Difficult |
| Flat-panel detector (if fitted) | Major service part | $$$$ | Difficult |
| C-arm friction-brake / bearing kit | Major service part | $$ | Moderate |
| Monitor / video cable | Major service part | $$ | Fairly easy |
| Cooling fan | Periodic replacement | $ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Synced live from the FDA openFDA API.
Images display with wrong patient demographics.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio