Toshiba · Model Aquilion RXL
With the integration of AIDR 3D into SUREExposure controls, radiation exposure is automatically reduced before the scan, ensuring that the lowest possible dose is employed for the specific diagnostic objective irrespective of the size or shape of the patient. AIDR 3D integrated in SUREExposure 3D Adaptive can be applied to all acquisition modes for routine clinical use and is able to remove up to 50% of image noise resulting, which corresponds to a dose reduction of up to 75% by the same Standard Deviation (SD) for noise. Key features of AIDR 3D: • Full integration in scan protocols for improved workflow • Dose reduction in clinical setting by up to 75% • Full automatic iterative reconstruction process • Minimal penalty in reconstruction times • Noise reduction and improved Spatial Resolution • Superb artifact suppression Lightning Speed The new console enables significant improvements in workflow, with faster reconstruction, automated processing,and remote access capabilities. With a reconstruction speed of up to 28* images per second (16 images per second for standard configuration), all the images are available in a flash, even when Toshiba’s unique 0.5 mm slice thickness is used. Furthermore, the enhanced DICOM protocol allows fast data transfer speed up to 60 images per second. Generation of MPR images can be performed automatically in accordance with the exam protocol setting. • High-Speed Reconstruction • Automated Processing • SUREXtension™ (Remote Access)* Latest Applications • Cardiac Examinations* • Colon View* • Lung Volume Analysis* • Vessel View* • Fat Index View* and more..
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Unexpected shutdown, unit won't power on.
Root cause: PSU or backup battery aging.
Symptoms: Frozen console, acquisition timeout.
Root cause: Workstation or storage degradation.
Symptoms: Images fail to transfer, PACS timeout.
Root cause: Network configuration or interface card fault.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Workstation / GPU | Periodic replacement | $$$ | Difficult |
| Power supply unit | Major service part | $$ | Moderate |
| Network interface card | Major service part | $ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →