Toshiba · Model Aquilion RX
Ultra Low Dose Examinations This system incorporates a variety of functions that can significantly reduce the patient exposure dose, such as AIDR, SUREExposureTM 3D, and Boost3DTM as standard. AIDR uses an iterative algorithm to reduce image noise while maintaining details and structural edges. The patient dose can be significantly reduced without negatively affecting image quality. Ultra High Patient Throughput A new computer platform for AquilionTM RX provides a 60% faster reconstruction time, allowing rapid diagnosis and promoting more efficient clinical workflow. Ultra Fast MPR Generation Generation of MPR images can be performed automatically in accordance with the exam protocol setting. Ultra Fast Data Transfer Enhanced DICOM protocol allows fast data transfer speed up to 60 images per second. Automated data transfer to multiple destination can be set in exam protocol setting. Adaptable console options - 1 or 2 Scan and display consoles maximize workflow. Both consoles can be operated independently, enabling parallel processing, significantly improving the efficiency of image processing and diagnosis. Powerful postprocessing CT application - on your own computer SUREXtension offers remote access to Aquilion’s advanced display console functions and clinical applications from your own computer on the hospital network. This thin-client display station makes it possible to review images anywhere in the hospital without relying on a PACS system, increasing patient throughput and shortening waiting times.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Tube won't fire, heat-capacity alarm.
Root cause: Filament wear, cooling failure.
Symptoms: Image noise, artifacts, low SNR.
Root cause: Flat-panel / sensor aging.
Symptoms: Tube temp alarm, duty-cycle limited.
Root cause: Pump/radiator or coolant loss.
Symptoms: Exposure fails, kV/mA out of range error.
Root cause: HV tank or generator board fault.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Major R&R; track mAs history.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| High-voltage generator | Major service part | $$$$ | Expert-level |
| Workstation RAID / GPU | Periodic replacement | $$$ | Difficult |
| X-ray tube insert Major R&R; track mAs history. | Major service part | $$$$ | Expert-level |
| Flat-panel detector | Major service part | $$$$ | Expert-level |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.