Toshiba · Model Aquilion Prime
Ultra Low Dose Examination AquilionTM PRIME incorporates Toshibas latest technologies to reduce exposure dose, while maintaining high image quality. • AIDR • Active Collimator • SUREExposure 3D • Boost3D • Dose Report • Dose Index Value Display Ultra Fast Workflow Aquilion PRIME ensures fast data to diagnosis that meets the requirements of increasingly complex examinations and accelerate the process of providing the information you need to make treatment decisions. • Fast Reconstruction • 80-detector row helical • 78 cm gantry aperture • Metal less Head rest • Metal less Arm up holder • SUREXtension ONE Family Application • Body Perfusion • Dual Energy • Lung Volume Measurement • SURECardio • CBP Study / SURESubtraction
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Unexpected shutdown, unit won't power on.
Root cause: PSU or backup battery aging.
Symptoms: Frozen console, acquisition timeout.
Root cause: Workstation or storage degradation.
Symptoms: Images fail to transfer, PACS timeout.
Root cause: Network configuration or interface card fault.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Network interface card | Major service part | $ | Fairly easy |
| Workstation / GPU | Periodic replacement | $$$ | Difficult |
| Power supply unit | Major service part | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.