Toshiba · Model Aquilion CX
• Premium 64 row Quantum-detector technology • Industry's best low contrast resolution of 2 mm • 72 kW generator with 350 ms rotation for increased flexibility • Up to 28 images per second reconstruction provides results in an instant • High definition coneXact 128-slice reconstruction with 0.31 mm Z-resolution • QDS noise and dose reduction for an effective patient dose reduction of 40% or more. • Advanced automated SURETechnologies such as SURESubtraction and SURECardio Prospective for better results at lower dose • PhaseXact a unique method for full automatic "Best Cardiac Phase" selection ánd reconstruction • 660 lb. patient weight capacity and the industry's widest couch increase your ability to accommodate larger patients • Gantry and couch return to home position automatically with the push of a button • Convenient front and rear table footswitches* facilitate a more efficient workflow
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Unexpected shutdown, unit won't power on.
Root cause: PSU or backup battery aging.
Symptoms: Frozen console, acquisition timeout.
Root cause: Workstation or storage degradation.
Symptoms: Images fail to transfer, PACS timeout.
Root cause: Network configuration or interface card fault.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Network interface card | Major service part | $ | Fairly easy |
| Workstation / GPU | Periodic replacement | $$$ | Difficult |
| Power supply unit | Major service part | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.