TOMY · Model KITMAN-T24
• Easy-To-See LED Display - The control panel features easy-to-see LED display that allows the operator to easily confirm a set temperature, speed and time at a glance • Convenient Function Keys - Function keys allow settings to be changed or modified to suit specific requirements • Two-Mode "FLASH" Function - "FLASH" or a quick run function for momentary spin provides the following two modes • Power Saving Mode - When operation standby status continues for a long time, the power saving mode becomes active and stops the fan and refrigerator. During the power saving mode, the panel display indicates "oFF". The idle time before the power saving mode is entered can be set between 1 and 12 hours. (The default time is 4 hours.) • PRE-TEMP Function - With the PRE-TEMP function air inside the chamber is stirred by spinning the rotor, which allows the rotor to reach set temperature quickly. It takes approximately 5 minutes to reach the set temperature of 4°C from the ambient temperature of 25°C. The result is an optimal function that supports temperature-sensitive samples. When the temperature inside the chamber increases in the power saving mode, the function can also cool the chamber effectively, saving time and energy • Easy-To-Install Compact Design - Its compact body with a width of 29cm takes up very little lab space • High Grade, Affordable Centrifuge - Equipped with upgraded functions, the TOMY "KITMAN" delivers higher performance at an affordable price
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
Consumable - replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
| Peristaltic pump tubing Consumable - replace proactively. | Frequent wear item | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →