Thermo Scientific · Model SL 16
Auto-Lock® III Rotor System - Exchange rotors in less than 3 seconds with the push of a button for quick switch between applications and cleaning convenience. ClickSeal® Bucket Sealing System - Porton Down certified, glove-friendly, one-handed snap-on covers replace screw caps and clips. Intuitive Controls - Advanced display and program recall keys let you monitor key data across the lab, and accelerate your daily programming. SMARTSpin® Rotor Management System - Optimize acceleration, braking and residual load imbalance for maximum safety and reproducible separations. Motorized Lid Latch - Improve closure time and reduce wear with one finger downward motion and optional automatic lid opening at the end of the run. Compact, Comfortable Design - Space-saving dimensions maximize workspace while ergonomic height and curved design ensure comfortable sample loading and unloading and easy cleaning. Excellent Capacity and Productivity - Choose from a wide range of rotors to meet your daily routine processing requirements, including new swinging bucket rotors for the highest configuration flexibility on the market, a dedicated rotor for standard and deep-well plates with optional sealed carriers, the 8x50 individually sealed rotor ideal for TB sputum applications, and the CLINIConic® rotor for cell culture and blood separation applications with 30 x 15 ml tubes.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Error code, run will not begin, or aborts shortly after start.
Root cause: Set speed exceeds the rotor maximum, an imbalanced load, the lid / door not locked, an unapproved rotor, or a drive / control fault.
Symptoms: Slow spin-up, rumble, or vibration during a run.
Root cause: Load imbalance, worn drive / motor bearings, a worn drive coupling, or (older units) worn motor brushes.
Symptoms: Run ends early / late, or RPM does not match the setting.
Root cause: Tacho / speed-sensor drift or a control-board fault.
Symptoms: Lid-lock error, will not open after a run, or will not lock to start.
Root cause: Lid-lock solenoid / switch fault, or a run still winding down.
Symptoms: Visible corrosion, cracks, or a bucket that will not swing; imbalance trips.
Root cause: Rotor / bucket ageing - a safety-critical wear item with a use-life limit.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
Log rotor runs; retire per the manufacturer's rotor-life programme.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Drive / motor bearings & coupling | Major service part | $$$ | Difficult |
| Lid-lock solenoid / switch | Major service part | $$ | Moderate |
| Speed sensor / control board | Major service part | $$ | Moderate |
| Motor brushes (older units) | Periodic replacement | $ | Moderate |
| Rotor / bucket set & O-rings Log rotor runs; retire per the manufacturer's rotor-life programme. | Major service part | $$$ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
From BioLab, for work done with this kind of equipment.