Thermo Scientific · Model MR23i
For maximum productivity: 23,000 rpm, 36,668 x g. A wide range of tube sizes are supported – from 0.2 ml up to 200 ml – to easily accommodate the different sample formats required in microbiology, molecular biology, genetics and biochemistry. Absolute security: Sealed rotors are CAMR-approved* for microbial integrity. Lifetime reproducibility: Guaranteed run to run by automatic High Reproducibility Factor (integral). True RCF: Using programmed radius allowing for use of adapters. Ready for use: 32 program memory with direct recall. Protection: Individual password protection of programs. Informative display: Alphanumeric 20 character with message readout. Versatile: Display in four languages; English, Spanish, Frencha and German. Suits all samples: Ten acceleration and ten braking rates (100 run profiles) treat even density gradients with care. Exceptionally quiet: Only 57 dBA at 23,000 rpm. Powerful refrigeration: Ensure samples are maintained at 4°C even at maximum speed(1).1) When using aluminum rotors. Maintenance-free: Induction motor. Safe: Imbalance detection and shutdown, guard barrier, dual lid interlock, current and temperature limitation.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Error code, run will not begin, or aborts shortly after start.
Root cause: Set speed exceeds the rotor maximum, an imbalanced load, the lid / door not locked, an unapproved rotor, or a drive / control fault.
Symptoms: Slow spin-up, rumble, or vibration during a run.
Root cause: Load imbalance, worn drive / motor bearings, a worn drive coupling, or (older units) worn motor brushes.
Symptoms: Run ends early / late, or RPM does not match the setting.
Root cause: Tacho / speed-sensor drift or a control-board fault.
Symptoms: Lid-lock error, will not open after a run, or will not lock to start.
Root cause: Lid-lock solenoid / switch fault, or a run still winding down.
Symptoms: Visible corrosion, cracks, or a bucket that will not swing; imbalance trips.
Root cause: Rotor / bucket ageing - a safety-critical wear item with a use-life limit.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
Log rotor runs; retire per the manufacturer's rotor-life programme.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Drive / motor bearings & coupling | Major service part | $$$ | Difficult |
| Lid-lock solenoid / switch | Major service part | $$ | Moderate |
| Speed sensor / control board | Major service part | $$ | Moderate |
| Motor brushes (older units) | Periodic replacement | $ | Moderate |
| Rotor / bucket set & O-rings Log rotor runs; retire per the manufacturer's rotor-life programme. | Major service part | $$$ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
From BioLab, for work done with this kind of equipment.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio