Thermo Scientific · Model MR23i
• For maximum productivity: 23,000 rpm, 36,668 x g • A wide range of tube sizes are supported – from 0.2 ml up to 200 ml – to easily accommodate the different sample formats required in microbiology, molecular biology,genetics and biochemistry. • Absolute security: Sealed rotors are CAMR-approved* for microbial integrity. • Lifetime reproducibility: Guaranteed run to run by automatic High Reproducibility Factor (integral). • True RCF: Using programmed radius allowing for use of adapters. • Ready for use: 32 program memory with direct recall. • Protection: Individual password protection of programs. • Informative display: Alphanumeric 20 character with message readout. • Versatile: Display in four languages; English, Spanish, Frencha and German. • Suits all samples: Ten acceleration and ten braking rates (100 run profiles) treat even density gradients with care. • Exceptionally quiet: Only 57 dBA at 23,000 rpm. • Powerful refrigeration: Ensure samples are maintained at 4°C even at maximum speed(1).1) When using aluminum rotors • Maintenance-free: Induction motor. • Safe: Imbalance detection and shutdown, guard barrier, dual lid interlock, current and temperature limitation.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
Consumable - replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
| Peristaltic pump tubing Consumable - replace proactively. | Frequent wear item | $ | Easy |
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.