Thermo Scientific · Model KR25i
• SuperspeedHigh Security: JOUAN's patented AUTO-LOCK® ensures that the rotor is locked onto the drive at run start. At run end the rotor can be removed without tools. • Intuitive controls: VIDEOsetTM graphic control system with pictures, messages and graph of the run. • Full information: Display of all set and actual parameter values including speed, RCF, time, temperature, integral, rotor, radius, acceleration, and braking rates. • High precision: Microprocessor control of all parameters. • Lifetime reproducibility: Guaranteed run to run by automatic High Reproducibility Factor (integral). • True RCF: Using programmed radius allowing for use of adaptors. • Ideal for process development: 24 program memory. • Heat labile sample protection: Thin Film Technology (TFT) twin skin controls -8 to +40°C with easily 4°C at full load, full speed, any rotor. • Accurate temperature control: Patented temperature sensor and software independent of the bowl for better sample temperature control. • Convenient: Carbon fiber composite large volume rotors; half the weight of alloy rotors. • Space saving: Only 27” (69 cm) deep; can fit into a run of benches. • Simple installation: The rear foot can be lowered by a person standing in front of the machine. • Maintenance-free motor: Quiet, brushless induction motor, designed and manufactured by Thermo. • Absolute safety: Sealed buckets and microplate carriers certified to IEC 1010-2-020 for biocontainment by C.A.M.R. Porton Down. Imbalance detection and shutdown, guard barrier, dual lid interlock, current and temperature limitation.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
Consumable - replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
| Peristaltic pump tubing Consumable - replace proactively. | Frequent wear item | $ | Easy |
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.