Thermo Scientific · Model KR25i
SuperspeedHigh Security: JOUAN's patented AUTO-LOCK® ensures that the rotor is locked onto the drive at run start. At run end the rotor can be removed without tools. Intuitive controls: VIDEOsetTM graphic control system with pictures, messages and graph of the run. Full information: Display of all set and actual parameter values including speed, RCF, time, temperature, integral, rotor, radius, acceleration, and braking rates. High precision: Microprocessor control of all parameters. Lifetime reproducibility: Guaranteed run to run by automatic High Reproducibility Factor (integral). True RCF: Using programmed radius allowing for use of adaptors. Ideal for process development: 24 program memory. Heat labile sample protection: Thin Film Technology (TFT) twin skin controls -8 to +40°C with easily 4°C at full load, full speed, any rotor. Accurate temperature control: Patented temperature sensor and software independent of the bowl for better sample temperature control. Convenient: Carbon fiber composite large volume rotors; half the weight of alloy rotors. Space saving: Only 27” (69 cm) deep; can fit into a run of benches. Simple installation: The rear foot can be lowered by a person standing in front of the machine. Maintenance-free motor: Quiet, brushless induction motor, designed and manufactured by Thermo. Absolute safety: Sealed buckets and microplate carriers certified to IEC 1010-2-020 for biocontainment by C.A.M.R. Porton Down. Imbalance detection and shutdown, guard barrier, dual lid interlock, current and temperature limitation.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Error code, run will not begin, or aborts shortly after start.
Root cause: Set speed exceeds the rotor maximum, an imbalanced load, the lid / door not locked, an unapproved rotor, or a drive / control fault.
Symptoms: Slow spin-up, rumble, or vibration during a run.
Root cause: Load imbalance, worn drive / motor bearings, a worn drive coupling, or (older units) worn motor brushes.
Symptoms: Run ends early / late, or RPM does not match the setting.
Root cause: Tacho / speed-sensor drift or a control-board fault.
Symptoms: Lid-lock error, will not open after a run, or will not lock to start.
Root cause: Lid-lock solenoid / switch fault, or a run still winding down.
Symptoms: Visible corrosion, cracks, or a bucket that will not swing; imbalance trips.
Root cause: Rotor / bucket ageing - a safety-critical wear item with a use-life limit.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
Log rotor runs; retire per the manufacturer's rotor-life programme.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Drive / motor bearings & coupling | Major service part | $$$ | Difficult |
| Lid-lock solenoid / switch | Major service part | $$ | Moderate |
| Speed sensor / control board | Major service part | $$ | Moderate |
| Motor brushes (older units) | Periodic replacement | $ | Moderate |
| Rotor / bucket set & O-rings Log rotor runs; retire per the manufacturer's rotor-life programme. | Major service part | $$$ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
From BioLab, for work done with this kind of equipment.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio