Thermo Scientific · Model Jouan G4i
Intuitive Control Panel • Protocols can be saved in five memory locations on the panel for instant recall with a single keystroke. • For each protocol, centrifugation time, speed, 'g' force, temperature, acceleration and braking rates can be selected. Both 'set' parameters and actual run conditions can be displayed and modified in real time. • Precise RCF setting and display can be achieved for any kind of adapter or container simply by programming the radius to within 1 mm; automatic rotor recognition prevents rotors from exceeding allowed speeds. Reliable and Repeatable Runs • The Jouan C4i/G4i incorporates precise microprocessor-based controls that ensure reproducible runs in conformity with GLP standards. • To adjust protocols for spinning very fragile samples, the C4i/G4i software provides 5 acceleration and 5 braking profiles. This permits the minimum run time to be achieved, while avoiding resuspension of the pellet. Precise Temperature Control • Ventilated C4i and G4i models provide centrifugation at room temperature, with minimal sample temperature increase. • Refrigerated CR4i and GR4i models are equipped with a powerful refrigeration system, offering settings from -9°C to 40°C. • Excellent cooling performance is provided, even at maximum speeds. 4°C is easily maintained at full load, full speed, and with any rotor.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
Consumable - replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
| Peristaltic pump tubing Consumable - replace proactively. | Frequent wear item | $ | Easy |
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.