Thermo Scientific · Model Heraeus Multifuge X3
• Increased Capacity and Processing Throughput - Process up to 40 x 50 ml conical tubes (40% more) in a swinging bucket rotor, or up to 14 x 50 ml (100% more) in fixed angle configuration, for significantly increased capacity over competitive models in the same bench space. • Broad Range of Rotors - For exceptional versatility, the Heraeus Multifuge X3 supports the broadest range of rotors and adapters available, including Thermo Scientific Fiberlite rotors, for a minimum of 16 rotor configurations. • Energy Efficiency - Achieve up to 40% energy consumption savings on industry standard protocols, such as blood separation or conical tubes processing, with the Heraeus Multifuge X3. • Space-Savings Design - Realize exceptional capability in compact dimensions for maximized workspace, and with ergonomic height and curved design ensure comfortable loading and unloading of samples and cleaning of the unit. • Advanced, Intuitive Programmable Controls - Detailed operation information, including display of set and actual parameters, maximize run performance and temperature accuracy for improved sample protection. Easily adjust speed, time and temperature, even during the run with our convenient keyboard for direct input. • Protection for Temperature Sensitive Samples - For high-performance applications with temperature-sensitive samples, the chamber and sample control is available between -10° and +40°C. With our double temperature management system, display the air temperature in the chamber as well as the sample temperature, ensuring accurate control of the sample temperature during the run. • Auto-Lock® III Rotor System - A secure locking system allows easy push-button installation and exchange of rotors for quick switch between applications and time savings. Also, easy access to the chamber enables quick cleaning, a healthier working environment and longer unit life. • ClickSeal® Bucket Sealing System - THERMO SCIENTIFIC's biocontainment solution, certified by CAMR in Porton Down, UK, allows simple operation eliminating screw caps and complicated clips as well as glove-friendly, one-handed open/close capability. • Motorized Lid Latch - Improve closure time and reduce wear with our highly reliable, hybrid lid latch system -combining the advantages of mechanical and electromechnical systems. This patented technology enables one finger downward motion for easiest closing and locking of centrifuge lid- even on tall benches with optional automatic lid opening. • SMARTSpin® Technology - The advanced rotor management system maximizes acceleration, braking and residual load imbalance for each rotor and bucket option, optimizing safety and improving separations.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.