Thermo Scientific · Model HERAEUS Multifuge 3S Plus
Unmatched versatility, exceptional throughput - Nine swinging-bucket rotor configurations and seven fixed-angle rotors give the Heraeus Multifuge 3 Plus Series unmatched versatility, making it a cost-effective investment for any lab. Unsurpassed productivity with high-capacity accessories - New carbon fiber rotors from FIBERLite® provide an advanced alternative to traditional metal rotors. Enhanced user and sample safety - The SMARTspin® imbalance detection system allows for eye balancing of samples with automatic termination of a run if excessive imbalance occurs. Modular, ergonomic design - The low deck height - just 31cm high - allows for easy loading and unloading of samples. The unique soft-touch lid effortlessly clicks into place for worry-free centrifugation. User-friendly operation - The EASYset™ soft-touch keypad allows for one-touch control of speed, programming and pre-cooling functions. Exceptional reliability -The brushless induction drive system guarantees years of dependable performance with minimal maintenance along with whisper-quiet operation and powerful acceleration and braking. A bright, easy-to-read LED display allows easy monitoring from across the lab. Automatic rotor recognition ensures precise rotor performance while preventing the use of incorrect accessories or parameters. Lightweight and easy to handle, these rotors generate less wear on the centrifuge motor and are resistant to corrosion, fatigue and repeated autoclaving. Spin up to 14 x 50 ml conical tubes in a single run. Achieve superspeed performance with RCFs over 24,000 x g on the benchtop. Safely perform high RCF, single-step separations using sterile, disposable conical tubes. Rotor systems designed to handle up to 108 x 5/7 ml blood collection tubes, 28 x 50 ml conical tubes or 6 x 250 ml bottles in a single run allow you to achieve greater levels of productivity.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Error code, run will not begin, or aborts shortly after start.
Root cause: Set speed exceeds the rotor maximum, an imbalanced load, the lid / door not locked, an unapproved rotor, or a drive / control fault.
Symptoms: Slow spin-up, rumble, or vibration during a run.
Root cause: Load imbalance, worn drive / motor bearings, a worn drive coupling, or (older units) worn motor brushes.
Symptoms: Run ends early / late, or RPM does not match the setting.
Root cause: Tacho / speed-sensor drift or a control-board fault.
Symptoms: Lid-lock error, will not open after a run, or will not lock to start.
Root cause: Lid-lock solenoid / switch fault, or a run still winding down.
Symptoms: Visible corrosion, cracks, or a bucket that will not swing; imbalance trips.
Root cause: Rotor / bucket ageing - a safety-critical wear item with a use-life limit.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
Log rotor runs; retire per the manufacturer's rotor-life programme.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Drive / motor bearings & coupling | Major service part | $$$ | Difficult |
| Lid-lock solenoid / switch | Major service part | $$ | Moderate |
| Speed sensor / control board | Major service part | $$ | Moderate |
| Motor brushes (older units) | Periodic replacement | $ | Moderate |
| Rotor / bucket set & O-rings Log rotor runs; retire per the manufacturer's rotor-life programme. | Major service part | $$$ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.