Thermo Scientific · Model Heraeus Labofuge 300
THERMO SCIENTIFIC Heraeus Labofuge 300 Small Medical Benchtop Centrifuge A small centrifuge with swinging bucket rotor, the Labofuge® 300 is used by medical practices and labs with low sample throughput. In addition to processing “gel tubes,” the unit also spins ordinary blood sample and glass tubes. In the field of virus testing, tubes with a gel barrier (“gel tubes”) are increasingly used. Immediately after a blood sample has been taken, these tubes must be spun. Once centrifugation is complete, the blood plasma is separated from red blood cells by a layer of gel. This gel layer prevents mixing and resultant decomposition of viruses. Unlike fixed angle rotors, which can lead to contamination within the gel tube, the Labofuge 300’s swinging bucket rotor ensures the gel barrier sticks to the tube wall with no traces of contamination in the plasma. The tubes can then be stored or transported to a laboratory for virus testing.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →