Thermo Scientific · Model HERAEUS Cryofuge 6000i & 8500i
• User friendly - Automatic lid locks enables the Cryofuge to be closed easily. Main control functions are conveniently arranged for easy access and the Cryofuge is equipped with 33 centrifuge programs for routine applications. Speed is controlled digitally with automatic RCF adjustments. Centrifuges can also be connected to a computer for data recording via a serial interface. • Powerful technology - The Cryofuge is equipped with a powerful, maintenance free induction drive for quiet and smooth operation. Its refrigeration system uses the environmentally friendly CFC free refrigerant R 404a. • Safety - When designing the Cryofuge, all international national safety standards were kept in mind to guarantee the highest level of safety. Diagnostic and fault messages are clearly visible. Pre-selecting of buckets protects against over-speeding. Steel armoured rotor chamber and lid lock system ensure safe operation. A key switch safeguards against unauthorized use. • GMP Centrifuges - The Cryofuge 6000i GMP (Good Manufacturing Practice) offers the same performance and accessories as the Cryofuge 6000i. The Cryofuge 8500i GMP attains a maximum centrifugal force of 8525 x g and a maximum speed of 5050 rpm. GMP Cryofuges are specially designed for use in clean room applications. • Data documentation - The Thermo Scientific HERANET data documentation system is available for data documentation in accordance with GMP. Safety Features: • Lid lock and interlock • Imbalance cut-ou • Steel armoured chamber
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
Consumable, replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
| Peristaltic pump tubing Consumable, replace proactively. | Frequent wear item | $ | Easy |
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.