Thermo Fisher Scientific · Model Medifuge Small Benchtop Centrifuge
Each Medifuge centrifuge comes as a package, including: Medifuge small benchtop centrifuge DualSpin rotor body Fixed angle buckets (set of 8) Swinging buckets (set of 8) Green/short spacers (set of 8) Yellow/long spacers (set of 8) Unique DualSpin rotor, features hybrid design with interchangeable fixed angle and swinging buckets Lightweight composite rotor is easy to handle and saves energy during acceleration/deceleration Large, brightly-lit display is easy to read and fast one-click lid closure simplifies operation Four customizable programs to quickly run routine protocols Three selectable deceleration profiles including brake-off option are designed to optimize separation Quiet operation at noise level less than 56 dBA Emergency lid lock release available in case of power failure Certifications: UL, CE, RoHS, CSA, IVD, FDA class 1 Standards: IEC 61010-1, IEC 61010-2-020, IEC 61010-2-101, EN 61326-1, EN ISO 13485
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
Consumable, replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
| Peristaltic pump tubing Consumable, replace proactively. | Frequent wear item | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →