TECHNIX · Model TCA 6S
Mobile C-Arm The TCA6 is a highly optimized Mobile Fluoroscopic System for surgery. The optimization that has been obtained through an intensive Research and Development effort, is the pursuit of the best compromise within the peculiar features of such an instrument: dimensions, weight, balancing, ease of manoeuvre, X-ray features, image quality, safety. The large achievable distance of the SID axis from the units stand, the noticeable motorized column elevation, reaching 500 millimeters, the wide C-arms insertion and span spaces, enable the best operational flexibility and the complete freedom of movement of the Surgeon in the operating theater, in the confines of the sterile area. A suitable C-arm-cross-sections profile, ensures flexural rigidity of the element, even in the most critical configuration with rotating anode tube monoblock X-ray generator and 9 Image Intensifier, for a high precision preservation of the X-ray beam centre, also in the horizontal projections. The TCA5 S&R can be fitted with a LASER targeting system that, from the monoblock and towards the intensifier, allows the identification of the beam centre, through a light cross: by means of this device, the preliminary positioning of the fluoroscopy system is possible, by reducing the X-ray dose to the patient.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Image noise, artifacts, low SNR.
Root cause: Flat-panel / sensor aging.
Symptoms: Tube temp alarm, duty-cycle limited.
Root cause: Pump/radiator or coolant loss.
Symptoms: Exposure fails, kV/mA out of range error.
Root cause: HV tank or generator board fault.
Symptoms: Frozen console, acquisition timeout.
Root cause: Workstation or RAID degradation.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Major R&R; track mAs history.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Workstation RAID / GPU | Periodic replacement | $$$ | Difficult |
| X-ray tube insert Major R&R; track mAs history. | Major service part | $$$$ | Expert-level |
| Flat-panel detector | Major service part | $$$$ | Expert-level |
| Cooling pump & radiator | Periodic replacement | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.