Tecan · Model HydroSpeed
Drop-wise dispensing to avoid cell detachment Optimization of dispense position to minimize turbulence in the wells Tunable aspiration parameters, including needle position and vacuum level, to avoid cell loss Reduced costs by eliminating the need for a dedicated cell washing head Automated start of rinse and soak steps of the wash head to avoid buffer crystallization Fail-safe procedure in case user has forgotten to start daily maintenance program No downtime for cleaning of spills typically caused by needle blockage Easy X-change wash heads allows additional intense cleaning in an external ultrasonic bath Powerful rare-earth magnets to provide fast and efficient bead settling Two magnets per well to keep the beads out of the way during washing Adjustable vacuum level and aspiration position for optimized bead recovery.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Readings biased or noisy, calibration / self-test fails, poor plate-to-plate reproducibility.
Root cause: Lamp / LED ageing, dirty optics or filters, or a filter-wheel fault.
Symptoms: Plate not drawn in or positioned, carriage-error message, wells read at the wrong position.
Root cause: Worn transport belt / motor or a position-sensor fault.
Symptoms: Wells not aspirated / dispensed evenly, high residual volume, needles blocked.
Root cause: Blocked or bent manifold needles, or a pump / vacuum fault.
Symptoms: A specific wavelength reads wrong, filter not found.
Root cause: Damaged interference filter or a filter-wheel position fault.
Symptoms: Results will not calculate, print or transfer.
Root cause: Onboard software, printer, or the interface.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Lamp / LED source | Periodic replacement | $$ | Fairly easy |
| Interference filters / filter wheel | Major service part | $$ | Moderate |
| Plate-transport belt / motor | Periodic replacement | $$ | Moderate |
| Wash-manifold needles / pump tubing (washers) | Frequent wear item | $ | Fairly easy |
| Optics / detector board | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.