Sysmex · Model UF-100™and UF-50™
Simplicity - Operation of the uf is simple and familiar, just like many other automated systems in the laboratory. Simply load tubes onto the sampler and press Start. Then walk away. The analysis is automatic and completely unattended. You return to final results. Flexibility - Workstation design can be customized to further improve urinalysis work flow. You choose the uf autosampler configuration that complements your automated chemistry strip reader. The uf gives you the flexibility to create the complete workstation that best fits your laboratory’s needs. The sysmex uf-Series is the automation alternative that provides fast efficient testing, your way. Urinalysis is one of the highest volume and least automated testing areas in the clinical laboratory. The uf-Series fully automated urine cell analyzers bring simplicity, efficiency and flexibility to this labor intensive test. Simplicity Operation of the uf is simple and familiar, just like many other automated systems in the laboratory. Simply load tubes onto the sampler and press Start. Then walk away. The analysis is automatic and completely unattended. You return to final results. Fully Automated Urine Cell Analyzers Efficiency Made Simple Now, final urinalysis results are available in about a minute. Samples with significant pathological formed elements are automatically identified with a series of flags. The efficiency of the uf-Series analyzers frees technologists from the repetitive, time consuming task of visually identifying urinary formedelements. Automated, immediate analysis improves work flow resulting in faster turn around time of critical patient results
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
Consumable, replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
| Peristaltic pump tubing Consumable, replace proactively. | Frequent wear item | $ | Easy |
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.