Surgical Direct, Inc. · Model SD807-701
2.7mm, 70 Degree Arthroscope, 175mm Working Length, Autoclave, High Performance German Optics, Storz
Intended use: An endoscope with a rigid inserted portion intended for the visual examination and treatment of the interior of a joint (e.g., knee, shoulder, elbow). It is inserted into the body through an artificial orifice created by an incision made during arthroscopy. Anatomical images are transmitted to the user through relayed lens optics or a fibreoptic bundle. This device is typically used to examine structural damage to a joint, often from sports injuries. The arthroscope eyepiece is normally interfaced with a video camera. This is a reusable device.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Stiff angulation, image artifacts.
Root cause: Repeat flexing / reprocessing.
Symptoms: Fogging, failed leak test.
Root cause: Damaged outer sheath.
Symptoms: No/poor image, color error.
Root cause: Sensor or cable failure.
Symptoms: Poor suction / irrigation.
Root cause: Debris in working channel.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
High-value R&R.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Image sensor module | Periodic replacement | $$$$ | Expert-level |
| Working channel liner | Periodic replacement | $$$ | Difficult |
| Outer sheath / distal end | Periodic replacement | $$$$ | Expert-level |
| Angulation cable / mesh High-value R&R. | Periodic replacement | $$$$ | Expert-level |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →