Jiangsu Jiyuan Medical Technology Co .,Ltd. · Model JY-MIP-1000
CVBS/HDMI, ARMI, Image processor for medical endoscope.
Intended use: An electrically-powered device designed to receive and process the electronic signals sent from a video endoscope or endoscopic video camera; it does not include the endoscope nor light source and is not designed to control the endoscope. It may have additional features which compensate for/enhance the colour and light qualities provided. The resulting picture images are sent to and shown on a visual display unit (VDU), typically to assist the endoscope operator with an ongoing intervention and often to allow the patient visualization of the process; the images can be recorded on a video recorder or stored on computerized media.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: No exposure on the hand-switch, error code, images under- or over-exposed.
Root cause: Depleted battery, a hand-switch / exposure-relay fault, or an X-ray tube / HV generator fault.
Symptoms: Few exposures per charge, the powered drive is weak or dead, will not charge.
Root cause: Aged battery pack or a drive-motor / charger fault.
Symptoms: Blurry, noisy or low-contrast images despite correct technique.
Root cause: Tube focal-spot degradation, generator instability, or the DR detector / wireless link.
Symptoms: Collimator light out, arm drifts or will not hold position.
Root cause: Collimator lamp, or worn arm friction / counterbalance.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Battery pack | Frequent wear item | $$ | Fairly easy |
| X-ray tube / HV generator assembly | Major service part | $$$$ | Expert-level |
| Hand-switch / exposure relay | Periodic replacement | $$ | Moderate |
| Collimator lamp | Periodic replacement | $ | Fairly easy |
| Positioning-arm friction / counterbalance kit | Major service part | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.