Stryker · Model MV3
Promotes fall prevention Safely accommodates patients of various sizes Designed with dignity in mind Encourages independence
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Won't hold position, rolls when locked.
Root cause: Brake pad wear or linkage failure.
Symptoms: Hard to push straight, wobbles or drags.
Root cause: Bearing wear or a flat-spotted wheel.
Symptoms: Visible crack or looseness at a joint.
Root cause: Repeated load cycling.
Symptoms: Torn or cracked cover, exposed padding.
Root cause: Cleaning-chemical and UV degradation, routine wear.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable - replace on visible wear or tear.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Upholstery / seat or surface cover Consumable - replace on visible wear or tear. | Periodic replacement | $ | Easy |
| Frame hardware (bolts, pins, bushings) | Major service part | $ | Fairly easy |
| Caster wheel assembly | Periodic replacement | $$ | Fairly easy |
| Brake / wheel-lock mechanism | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Synced live from the FDA openFDA API.
Stryker has issued a voluntary recall of certain MV3 beds and Arise 1000EX mattresses because some of these products have been sold in close proximity, suggesting a potential intent for them to be used together. These products have not been tested for compatibility and thus are not designed to be used together. The combination of both is not recommended by Stryker.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →