Amico · Model Apollo TTS Bed
Standard Features 16" (41 cm) low height Unique siderail design adapted to comply with HBSW and IEC regulations Customized panels to suit the color scheme within the hospital facility 5" (13 cm) wheel casters Central locking brake mechanism Silent DC actuators Modular battery backup Electronic lock-out controls on outer siderails Auto-contour features when fowler is raised Patient controls on inner siderails Trendelenburg and reverse Trendelenburg HBSW - compliant siderails 550 lbs (250 kg) weight capacity Metal litter deck Integrated mattress retainer Integrated bed extender CPR release system Four IV pole sockets Two restraining strap holders Foley bag hook LED night light Four integrated roller bumpers Flat litter deck for compatibility with standard patient surfaces Integrated air mattress pump holder on footboard Optional Features and Accessories Pressure relief surfaces Siderail communications which includes nurse call and room/reading lights Removable IV pole 30° head of bed lockout Patient handset for motion controls 6" (15 cm) casters Brake not set alarm One-button chair function.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Backrest, knee, height, Trendelenburg or the TTS (turn) function will not move from the siderail or caregiver controls.
Root cause: Failed linear actuator, a control-board fault, a control-panel fault, or a pinched / damaged control cable.
Symptoms: The lateral turn assist will not inflate / turn, or turns unevenly.
Root cause: Turn-bladder leak, the turn pump / blower, or a distribution-valve fault.
Symptoms: Weight reads implausibly or will not zero, bed-exit alarm false-triggers or fails.
Root cause: Load-cell drift or damage, or a scale-control fault.
Symptoms: Bed will not brake or release, drifts, central brake pedal ineffective.
Root cause: Worn central-brake linkage or castor.
Symptoms: Functions and alarms do not work during a power interruption.
Root cause: Aged back-up battery or a charger fault.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
Recalibrate the scale after replacement.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Linear actuator (backrest / knee / height) | Major service part | $$$ | Difficult |
| Turn pump / blower & bladder | Periodic replacement | $$$ | Moderate |
| Load cell / scale sensor set Recalibrate the scale after replacement. | Major service part | $$$ | Difficult |
| Central-brake / castor assembly | Major service part | $$ | Difficult |
| Back-up battery | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.