Stryker · Model 720
Fold –down side rails help ensure patient safety 8in. (20 cm) Omni Surface casters Fold-to-foot side rails Four IV receptacles Four-wheel steel-ring brakes with dual end activators Integrated storage tray with an oxygen bottle holder Locking caster steering Roller bumpers Stationary foot-end litter
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Won't hold position, rolls when locked.
Root cause: Brake pad wear or linkage failure.
Symptoms: Hard to push straight, wobbles or drags.
Root cause: Bearing wear or a flat-spotted wheel.
Symptoms: Visible crack or looseness at a joint.
Root cause: Repeated load cycling.
Symptoms: Torn or cracked cover, exposed padding.
Root cause: Cleaning-chemical and UV degradation, routine wear.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable - replace on visible wear or tear.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Upholstery / seat or surface cover Consumable - replace on visible wear or tear. | Periodic replacement | $ | Easy |
| Frame hardware (bolts, pins, bushings) | Major service part | $ | Fairly easy |
| Caster wheel assembly | Periodic replacement | $$ | Fairly easy |
| Brake / wheel-lock mechanism | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Synced live from the FDA openFDA API.
Based on an accelerated aging test for this product packaging, there is an indicator of potential for a breach in the sterile barrier in the header bag and potentially the blue sterilization wrap for togas within the second and third year of shelf life. The test method used involved high heat to accelerate the aging of the packaging. Stryker is conducting additional testing and assessing this pr
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →