Stryker · Model 1488 HD
Image Brightness and Clarity High Noise Immunity Designed for Patient Safety – Enhanced light sensitivity of the 1488 allows the light source to run at lower power levels that can reduce the risk of patient/drape burns while still providing premium optical performance 9 Surgical Specialties – optimized performance to address the specific color and lighting needs of individual surgical procedures Stryker provides a comprehensive cross-specialty surgical solution designed to maximize the value of our customers’ investment in Stryker Enables standardization of video systems to one platform Customization of the surgical experience through 4 programmable camera buttons Activation of the L9000 LED Light Source and Wingman Scope Holder from the surgical field 10 button functions built scalable to increase with platform advancements Optical Zoom Coupler provides dynamic zoom range with no compromise in image clarity Infravision compatible to clearly identify critical anatomy.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: No light output, dim or flickering light, lamp-hours alarm, colour shift.
Root cause: Xenon / LED lamp at end of life, a lamp power supply fault, or a light-cable fault.
Symptoms: Noisy, dark, discoloured or out-of-focus image, dropouts, no image.
Root cause: Camera head / coupler fault, a camera-cable fault, or a CCU / video-processor fault.
Symptoms: Cannot white-balance, persistent colour cast.
Root cause: Camera head sensor drift, a dirty coupler, or the light source colour temperature.
Symptoms: Thermal shutdown, loud fan, hot exhaust.
Root cause: Failed or clogged cooling fan.
Symptoms: Signal only on one output, connector damage, HD/SDI dropout.
Root cause: Worn video output connector or an output board fault.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Xenon / LED lamp module | Frequent wear item | $$$ | Fairly easy |
| Camera head / coupler | Periodic replacement | $$$ | Moderate |
| Camera cable | Periodic replacement | $$ | Fairly easy |
| Fibre-optic light cable | Periodic replacement | $$ | Easy |
| CCU / video-processor board | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Synced live from the FDA openFDA API.
In certain operating room environments, a colored screen image occurs with the 1488 Cameras that were manufactured during a specific time period
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.