Olympus · Model Exera II CV-180
• Equipped with high-resolution HDTV imaging capability to assure the best-possible image quality for endoscopy and laparoscopy. This enables enhanced observation of capillaries • Compatible with EVIS 100/130/40 Series and EVIS EXERA™ 160 Series scopes as well as bronchoscopes and surgical endoscopes (EndoEYE™, 1CCD/3CCD camera head, and VISERA™ videoscopes) • Narrow Band Imaging™ (NBI) to enhance the visibility of fine capillaries and the mucosal tissues • Two types of structure enhancement are available the original Type A for observation of larger mucosal tissues with high contrast, and the new Type B for observation of smaller tissues, such as capillaries • Electronic magnification enlarges moving or still images by 1.2x or 1.5x with no loss of quality • Convenient recording of both still and moving images on xD cards or digital video cassettes using remote control switches. HD/SD SDI output for deterioration-free images • Automatic Iris eliminates the need for switching between Peak and Average required in conventional manual adjustment
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: No image, color shift, or visible artifacts.
Root cause: Image sensor or its driver board aging.
Symptoms: Intermittent signal or no image at the tower.
Root cause: Cable flex fatigue or connector pin wear.
Symptoms: Blurry, dark, or off-center image.
Root cause: Coupler or lens element misalignment/damage.
Symptoms: Color inaccuracy that won't correct on white-balance.
Root cause: Calibration drift or button/sensor fault.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
High-turnover; keep spares.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Coupler / lens assembly | Major service part | $$$ | Moderate |
| Camera control unit (CCU) | Major service part | $$$$ | Difficult |
| Camera head / sensor assembly | Periodic replacement | $$$$ | Difficult |
| Camera cable High-turnover; keep spares. | Periodic replacement | $$ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →