STERIS · Model Caviwave Pro
Automatically cleans, flushes, lubricates, and dries depending on unit configuration* CaviClean technology at 132kHz and 58kHz combines dual frequency scrubbing action Ergonomic automated tray for loading and unloading of surgical devices Capability to process new Xi™ instruments from Intuitive Surgical Multiple tank sizes and configurations to fit into your reprocessing space. Accessories available to allow compatibility of many different instruments and devices Automatic chemistry and lubrication injection** Can process up to 35lbs. of instruments. Drying tank CaviClean technology at 132kHz and 58kHz combines dual frequency scrubbing action Flush ports allow tank solution reach into internal passages. Delivers consistent results. Independently tested and validated by STERIS in partnership with Intuitive Surgical®
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Pressure loss, long cycle, steam leak.
Root cause: Aged rubber gasket.
Symptoms: No steam, low temp, cycle abort.
Root cause: Failed heating element or scale buildup.
Symptoms: Poor air removal, non-condensable gas fault.
Root cause: Worn vanes/seals.
Symptoms: Scaling, conductivity alarm.
Root cause: RO/DI system failure.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable.
Most-replaced wear item.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Vacuum pump & seals | Periodic replacement | $$$ | Difficult |
| Chamber temperature sensor | Periodic replacement | $$ | Moderate |
| RO/DI feed cartridge Consumable. | Frequent wear item | $ | Easy |
| Door gasket / seal Most-replaced wear item. | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →