Stephanix · Model Omniscop DReam-S
Easy positioning: With balanced movements, the easy positioning of the C-arm makes it simple and fast to place around the patient and the operating table. The compact design of the Omniscop DReam-S C-arm makes it easy to move from room to room. 360° access to images wherever you are, thanks to its large 27″ flat screen, high resolution 4K The large 12″ operator touch screen gives quick access to all protocols and acquisition parameters. Images are displayed in real time allowing instant control from the acquisition console. Omniscop DReam-S fits your needs by providing 2 sizes of aSi flat panel detectors: 21 x 21 cm and 30 x 30 cm, producing high resolution images up to 4 Mp. Removable grid for pediatric exams and specific procedures. Dual centering laser (optional), on the tube side and on the detector side, for positioning without x-rays and regardless of the position of the c-arm.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Tube won't fire, heat-capacity alarm.
Root cause: Filament wear, cooling failure.
Symptoms: Image noise, artifacts, low SNR.
Root cause: Flat-panel / sensor aging.
Symptoms: Tube temp alarm, duty-cycle limited.
Root cause: Pump/radiator or coolant loss.
Symptoms: Exposure fails, kV/mA out of range error.
Root cause: HV tank or generator board fault.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Major R&R; track mAs history.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| High-voltage generator | Major service part | $$$$ | Expert-level |
| Workstation RAID / GPU | Periodic replacement | $$$ | Difficult |
| X-ray tube insert Major R&R; track mAs history. | Major service part | $$$$ | Expert-level |
| Flat-panel detector | Major service part | $$$$ | Expert-level |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.